<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Novaris Archives - Uptime Systems Australia</title>
	<atom:link href="https://uptimes.com.au/brand/novaris/feed/" rel="self" type="application/rss+xml" />
	<link>https://uptimes.com.au/brand/novaris/</link>
	<description>Australia&#039;s Experts in Power Protection Product Solutions</description>
	<lastBuildDate>Fri, 09 Jan 2026 13:45:43 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://uptimes.com.au/wp-content/uploads/cropped-Uptimes-System-1-32x32.png</url>
	<title>Novaris Archives - Uptime Systems Australia</title>
	<link>https://uptimes.com.au/brand/novaris/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Novaris Plug-in Surge Filter 10A Eight (8) Outlets</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filter-10a-eight-8-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:56:34 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19917</guid>

					<description><![CDATA[<strong>PP10A8-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A8-50</strong></h3>
<table width="580">
<tbody>
<tr>
<td width="253"><strong>Electrical Specifications</strong></td>
<td width="327"></td>
</tr>
<tr>
<td>Connection type</td>
<td>Series</td>
</tr>
<tr>
<td>Modes of protection</td>
<td>All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr>
<td>Nominal voltage</td>
<td>230V / 50Hz</td>
</tr>
<tr>
<td>Maximum continuous voltage</td>
<td>275V / 50Hz</td>
</tr>
<tr>
<td>Maximum discharge current (8/20?s)</td>
<td>50kA</td>
</tr>
<tr>
<td>Nominal discharge current (15 x 8/20?s)</td>
<td>20kA</td>
</tr>
<tr>
<td>Maximum load current</td>
<td>10A</td>
</tr>
<tr>
<td>Protection stages</td>
<td>Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr>
<td>Voltage protection level @3kA (8/20?s)</td>
<td>&lt;600V</td>
</tr>
<tr>
<td>Response time</td>
<td>Instantaneous</td>
</tr>
<tr>
<td>Power Consumption (@230V 50Hz)</td>
<td>&lt;1W</td>
</tr>
<tr>
<td>Attenuation</td>
<td>-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr>
<td>Earth leakage current</td>
<td>&lt;500?A</td>
</tr>
<tr>
<td width="253">Maximum voltage drop (% of U0)</td>
<td>&lt;1%</td>
</tr>
<tr>
<td>Display</td>
<td>LED power and status</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Mechanical Specifications</strong></td>
<td></td>
</tr>
<tr>
<td>Operating temperature / humidity</td>
<td>-40 to +70?C / 0 to 90% non-condensing</td>
</tr>
<tr>
<td>Connection type &#8211; line side cord</td>
<td>IEC C14 Inlet</td>
</tr>
<tr>
<td>Connection type &#8211; load side outlet</td>
<td>10A Australian (type I) outlet</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>8</td>
</tr>
<tr>
<td>Environmental</td>
<td>IP 20</td>
</tr>
<tr>
<td>Mounting</td>
<td>Freestanding, (optional wall mount -M)</td>
</tr>
<tr>
<td>Weight</td>
<td>1.3kg</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>305mm</td>
</tr>
<tr>
<td>Height</td>
<td>140mm</td>
</tr>
<tr>
<td>Depth</td>
<td>60mm</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Standards Compliance</strong></td>
<td>IEC 61643-11 class II, III</td>
</tr>
<tr>
<td></td>
<td>AS/NZS 1768 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEEE C62.41 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEC 1000-4-5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Six (6) Outlets</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filter-10a-six-6-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:45:15 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19916</guid>

					<description><![CDATA[<strong>PP10A6-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

<a class="button product_type_simple" title="Contact Uptime Systems Today!" href="https://uptimes.com.au/contactus/#contact-form">Contact us for Pricing</a>]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="19916" class="elementor elementor-19916" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-4b0b478a e-flex e-con-boxed e-con e-parent" data-id="4b0b478a" data-element_type="container">
					<div class="e-con-inner">
					</div>
				</div>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Four (4) Outlets</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filters-10a-four-4-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:37:36 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19915</guid>

					<description><![CDATA[<strong>PP10A4-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A4-50</strong></h3>
<table width="580">
<tbody>
<tr style="height: 23px;">
<td style="height: 23px;" width="253"><strong>Electrical Specifications</strong></td>
<td style="height: 23px;" width="327"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type</td>
<td style="height: 23px;">Series</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Modes of protection</td>
<td style="height: 23px;">All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Nominal voltage</td>
<td style="height: 23px;">230V / 50Hz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum continuous voltage</td>
<td style="height: 23px;">275V / 50Hz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum discharge current (8/20?s)</td>
<td style="height: 23px;">50kA</td>
</tr>
<tr style="height: 46px;">
<td style="height: 46px;">Nominal discharge current (15 x 8/20?s)</td>
<td style="height: 46px;">20kA</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum load current</td>
<td style="height: 23px;">10A</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Protection stages</td>
<td style="height: 23px;">Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Voltage protection level @3kA (8/20?s)</td>
<td style="height: 23px;">&lt;600V</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Response time</td>
<td style="height: 23px;">Instantaneous</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Power Consumption (@230V 50Hz)</td>
<td style="height: 23px;">&lt;1W</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Attenuation</td>
<td style="height: 23px;">-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Earth leakage current</td>
<td style="height: 23px;">&lt;500?A</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;" width="253">Maximum voltage drop (% of U0)</td>
<td style="height: 23px;">&lt;1%</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Display</td>
<td style="height: 23px;">LED power and status</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Mechanical Specifications</strong></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Operating temperature / humidity</td>
<td style="height: 23px;">-40 to +70?C / 0 to 90% non-condensing</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type &#8211; line side cord</td>
<td style="height: 23px;">IEC C14 Inlet</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type &#8211; load side outlet</td>
<td style="height: 23px;">10A Australian (type I) outlet</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Number of outlets</td>
<td style="height: 23px;">4</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Environmental</td>
<td style="height: 23px;">IP 20</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Mounting</td>
<td style="height: 23px;">Freestanding, (optional wall mount -M)</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Weight</td>
<td style="height: 23px;">1.3kg</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Dimensions</strong></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Width</td>
<td style="height: 23px;">205mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Height</td>
<td style="height: 23px;">140mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Depth</td>
<td style="height: 23px;">60mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Standards Compliance</strong></td>
<td style="height: 23px;">IEC 61643-11 class II, III</td>
</tr>
<tr style="height: 17.4609px;">
<td style="height: 17.4609px;"></td>
<td style="height: 17.4609px;">AS/NZS 1768 categories A, B</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;">IEEE C62.41 categories A, B</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;">IEC 1000-4-5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Two (2) Outlets</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filters-10a-two-2-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:32:12 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19913</guid>

					<description><![CDATA[<h3><strong>PP10A2-50</strong></h3>
Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

<a class="button product_type_simple" title="Contact Uptime Systems Today!" href="https://uptimes.com.au/contactus/#contact-form">Contact us for pricing</a>]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A2-50</strong></h3>
<table width="580">
<tbody>
<tr>
<td width="253"><strong>Electrical Specifications</strong></td>
<td width="327"></td>
</tr>
<tr>
<td>Connection type</td>
<td>Series</td>
</tr>
<tr>
<td>Modes of protection</td>
<td>All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr>
<td>Nominal voltage</td>
<td>230V / 50Hz</td>
</tr>
<tr>
<td>Maximum continuous voltage</td>
<td>275V / 50Hz</td>
</tr>
<tr>
<td>Maximum discharge current (8/20?s)</td>
<td>50kA</td>
</tr>
<tr>
<td>Nominal discharge current (15 x 8/20?s)</td>
<td>20kA</td>
</tr>
<tr>
<td>Maximum load current</td>
<td>10A</td>
</tr>
<tr>
<td>Protection stages</td>
<td>Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr>
<td>Voltage protection level @3kA (8/20?s)</td>
<td>&lt;600V</td>
</tr>
<tr>
<td>Response time</td>
<td>Instantaneous</td>
</tr>
<tr>
<td>Power Consumption (@230V 50Hz)</td>
<td>&lt;1W</td>
</tr>
<tr>
<td>Attenuation</td>
<td>-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr>
<td>Earth leakage current</td>
<td>&lt;500 A</td>
</tr>
<tr>
<td width="253">Maximum voltage drop (% of U0)</td>
<td>&lt;1%</td>
</tr>
<tr>
<td>Display</td>
<td>LED power and status</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Mechanical Specifications</strong></td>
<td></td>
</tr>
<tr>
<td>Operating temperature / humidity</td>
<td>-40 to +70 °C / 0 to 90% non-condensing</td>
</tr>
<tr>
<td>Connection type &#8211; line side cord</td>
<td>IEC C14 Inlet</td>
</tr>
<tr>
<td>Connection type &#8211; load side outlet</td>
<td>10A Australian (type I) outlet</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>2</td>
</tr>
<tr>
<td>Environmental</td>
<td>IP 20</td>
</tr>
<tr>
<td>Mounting</td>
<td>Freestanding, (optional wall mount -M)</td>
</tr>
<tr>
<td>Weight</td>
<td>1.3kg</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>155mm</td>
</tr>
<tr>
<td>Height</td>
<td>140mm</td>
</tr>
<tr>
<td>Depth</td>
<td>60mm</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Standards Compliance</strong></td>
<td>IEC 61643-11 class II, III</td>
</tr>
<tr>
<td></td>
<td>AS/NZS 1768 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEEE C62.41 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEC 1000-4-5</td>
</tr>
</tbody>