<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Surge Protection | Power &amp; Smart Surge Protectors Australia</title>
	<atom:link href="https://uptimes.com.au/product-category/shop-by-products/surge-protection/feed/" rel="self" type="application/rss+xml" />
	<link>https://uptimes.com.au/product-category/shop-by-products/surge-protection/</link>
	<description>Australia&#039;s Experts in Power Protection Product Solutions</description>
	<lastBuildDate>Fri, 09 Jan 2026 13:45:43 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://uptimes.com.au/wp-content/uploads/cropped-Uptimes-System-1-32x32.png</url>
	<title>Surge Protection | Power &amp; Smart Surge Protectors Australia</title>
	<link>https://uptimes.com.au/product-category/shop-by-products/surge-protection/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Novaris Plug-in Surge Filter 10A Eight (...</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filter-10a-eight-8-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:56:34 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19917</guid>

					<description><![CDATA[<strong>PP10A8-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A8-50</strong></h3>
<table width="580">
<tbody>
<tr>
<td width="253"><strong>Electrical Specifications</strong></td>
<td width="327"></td>
</tr>
<tr>
<td>Connection type</td>
<td>Series</td>
</tr>
<tr>
<td>Modes of protection</td>
<td>All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr>
<td>Nominal voltage</td>
<td>230V / 50Hz</td>
</tr>
<tr>
<td>Maximum continuous voltage</td>
<td>275V / 50Hz</td>
</tr>
<tr>
<td>Maximum discharge current (8/20?s)</td>
<td>50kA</td>
</tr>
<tr>
<td>Nominal discharge current (15 x 8/20?s)</td>
<td>20kA</td>
</tr>
<tr>
<td>Maximum load current</td>
<td>10A</td>
</tr>
<tr>
<td>Protection stages</td>
<td>Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr>
<td>Voltage protection level @3kA (8/20?s)</td>
<td>&lt;600V</td>
</tr>
<tr>
<td>Response time</td>
<td>Instantaneous</td>
</tr>
<tr>
<td>Power Consumption (@230V 50Hz)</td>
<td>&lt;1W</td>
</tr>
<tr>
<td>Attenuation</td>
<td>-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr>
<td>Earth leakage current</td>
<td>&lt;500?A</td>
</tr>
<tr>
<td width="253">Maximum voltage drop (% of U0)</td>
<td>&lt;1%</td>
</tr>
<tr>
<td>Display</td>
<td>LED power and status</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Mechanical Specifications</strong></td>
<td></td>
</tr>
<tr>
<td>Operating temperature / humidity</td>
<td>-40 to +70?C / 0 to 90% non-condensing</td>
</tr>
<tr>
<td>Connection type &#8211; line side cord</td>
<td>IEC C14 Inlet</td>
</tr>
<tr>
<td>Connection type &#8211; load side outlet</td>
<td>10A Australian (type I) outlet</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>8</td>
</tr>
<tr>
<td>Environmental</td>
<td>IP 20</td>
</tr>
<tr>
<td>Mounting</td>
<td>Freestanding, (optional wall mount -M)</td>
</tr>
<tr>
<td>Weight</td>
<td>1.3kg</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>305mm</td>
</tr>
<tr>
<td>Height</td>
<td>140mm</td>
</tr>
<tr>
<td>Depth</td>
<td>60mm</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Standards Compliance</strong></td>
<td>IEC 61643-11 class II, III</td>
</tr>
<tr>
<td></td>
<td>AS/NZS 1768 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEEE C62.41 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEC 1000-4-5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Six (6)...</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filter-10a-six-6-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:45:15 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19916</guid>

					<description><![CDATA[<strong>PP10A6-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

<a class="button product_type_simple" title="Contact Uptime Systems Today!" href="https://uptimes.com.au/contactus/#contact-form">Contact us for Pricing</a>]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="19916" class="elementor elementor-19916" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-4b0b478a e-flex e-con-boxed e-con e-parent" data-id="4b0b478a" data-element_type="container">
					<div class="e-con-inner">
					</div>
				</div>
				</div>
		]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Four (4...</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filters-10a-four-4-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:37:36 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19915</guid>

					<description><![CDATA[<strong>PP10A4-50</strong>

Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A4-50</strong></h3>
<table width="580">
<tbody>
<tr style="height: 23px;">
<td style="height: 23px;" width="253"><strong>Electrical Specifications</strong></td>
<td style="height: 23px;" width="327"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type</td>
<td style="height: 23px;">Series</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Modes of protection</td>
<td style="height: 23px;">All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Nominal voltage</td>
<td style="height: 23px;">230V / 50Hz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum continuous voltage</td>
<td style="height: 23px;">275V / 50Hz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum discharge current (8/20?s)</td>
<td style="height: 23px;">50kA</td>
</tr>
<tr style="height: 46px;">
<td style="height: 46px;">Nominal discharge current (15 x 8/20?s)</td>
<td style="height: 46px;">20kA</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Maximum load current</td>
<td style="height: 23px;">10A</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Protection stages</td>
<td style="height: 23px;">Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Voltage protection level @3kA (8/20?s)</td>
<td style="height: 23px;">&lt;600V</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Response time</td>
<td style="height: 23px;">Instantaneous</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Power Consumption (@230V 50Hz)</td>
<td style="height: 23px;">&lt;1W</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Attenuation</td>
<td style="height: 23px;">-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Earth leakage current</td>
<td style="height: 23px;">&lt;500?A</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;" width="253">Maximum voltage drop (% of U0)</td>
<td style="height: 23px;">&lt;1%</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Display</td>
<td style="height: 23px;">LED power and status</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Mechanical Specifications</strong></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Operating temperature / humidity</td>
<td style="height: 23px;">-40 to +70?C / 0 to 90% non-condensing</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type &#8211; line side cord</td>
<td style="height: 23px;">IEC C14 Inlet</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Connection type &#8211; load side outlet</td>
<td style="height: 23px;">10A Australian (type I) outlet</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Number of outlets</td>
<td style="height: 23px;">4</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Environmental</td>
<td style="height: 23px;">IP 20</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Mounting</td>
<td style="height: 23px;">Freestanding, (optional wall mount -M)</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Weight</td>
<td style="height: 23px;">1.3kg</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Dimensions</strong></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Width</td>
<td style="height: 23px;">205mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Height</td>
<td style="height: 23px;">140mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;">Depth</td>
<td style="height: 23px;">60mm</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;"></td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"><strong>Standards Compliance</strong></td>
<td style="height: 23px;">IEC 61643-11 class II, III</td>
</tr>
<tr style="height: 17.4609px;">
<td style="height: 17.4609px;"></td>
<td style="height: 17.4609px;">AS/NZS 1768 categories A, B</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;">IEEE C62.41 categories A, B</td>
</tr>
<tr style="height: 23px;">
<td style="height: 23px;"></td>
<td style="height: 23px;">IEC 1000-4-5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Novaris Plug-in Surge Filter 10A Two (2)...</title>
		<link>https://uptimes.com.au/product/novaris-plug-in-surge-filters-10a-two-2-outlets/</link>
		
		<dc:creator><![CDATA[Erwin Rebolledo]]></dc:creator>
		<pubDate>Mon, 01 Feb 2021 04:32:12 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=19913</guid>

					<description><![CDATA[<h3><strong>PP10A2-50</strong></h3>
Plug-in Surge Filter
Novaris plug-in surge filters plug into a standard mains outlet socket to provide premium protection for sensitive or critical electronic equipment.

<a class="button product_type_simple" title="Contact Uptime Systems Today!" href="https://uptimes.com.au/contactus/#contact-form">Contact us for pricing</a>]]></description>
										<content:encoded><![CDATA[<h3><strong>PP10A2-50</strong></h3>
<table width="580">
<tbody>
<tr>
<td width="253"><strong>Electrical Specifications</strong></td>
<td width="327"></td>
</tr>
<tr>
<td>Connection type</td>
<td>Series</td>
</tr>
<tr>
<td>Modes of protection</td>
<td>All mode (L-N, L-PE, N-PE)</td>
</tr>
<tr>
<td>Nominal voltage</td>
<td>230V / 50Hz</td>
</tr>
<tr>
<td>Maximum continuous voltage</td>
<td>275V / 50Hz</td>
</tr>
<tr>
<td>Maximum discharge current (8/20?s)</td>
<td>50kA</td>
</tr>
<tr>
<td>Nominal discharge current (15 x 8/20?s)</td>
<td>20kA</td>
</tr>
<tr>
<td>Maximum load current</td>
<td>10A</td>
</tr>
<tr>
<td>Protection stages</td>
<td>Metal oxide varistor / LC filter / Metal oxide varistor</td>
</tr>
<tr>
<td>Voltage protection level @3kA (8/20?s)</td>
<td>&lt;600V</td>
</tr>
<tr>
<td>Response time</td>
<td>Instantaneous</td>
</tr>
<tr>
<td>Power Consumption (@230V 50Hz)</td>
<td>&lt;1W</td>
</tr>
<tr>
<td>Attenuation</td>
<td>-3dB at 900Hz, -60dB at 100kHz</td>
</tr>
<tr>
<td>Earth leakage current</td>
<td>&lt;500 A</td>
</tr>
<tr>
<td width="253">Maximum voltage drop (% of U0)</td>
<td>&lt;1%</td>
</tr>
<tr>
<td>Display</td>
<td>LED power and status</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Mechanical Specifications</strong></td>
<td></td>
</tr>
<tr>
<td>Operating temperature / humidity</td>
<td>-40 to +70 °C / 0 to 90% non-condensing</td>
</tr>
<tr>
<td>Connection type &#8211; line side cord</td>
<td>IEC C14 Inlet</td>
</tr>
<tr>
<td>Connection type &#8211; load side outlet</td>
<td>10A Australian (type I) outlet</td>
</tr>
<tr>
<td>Number of outlets</td>
<td>2</td>
</tr>
<tr>
<td>Environmental</td>
<td>IP 20</td>
</tr>
<tr>
<td>Mounting</td>
<td>Freestanding, (optional wall mount -M)</td>
</tr>
<tr>
<td>Weight</td>
<td>1.3kg</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Dimensions</strong></td>
<td></td>
</tr>
<tr>
<td>Width</td>
<td>155mm</td>
</tr>
<tr>
<td>Height</td>
<td>140mm</td>
</tr>
<tr>
<td>Depth</td>
<td>60mm</td>
</tr>
<tr>
<td></td>
<td></td>
</tr>
<tr>
<td><strong>Standards Compliance</strong></td>
<td>IEC 61643-11 class II, III</td>
</tr>
<tr>
<td></td>
<td>AS/NZS 1768 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEEE C62.41 categories A, B</td>
</tr>
<tr>
<td></td>
<td>IEC 1000-4-5</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CyberPower Systems 8 Port Surge Protecto...</title>
		<link>https://uptimes.com.au/product/cyberpower-systems-8-port-surge-protector-powerboard-with-2x-usb-2-4a-quick-charge-ports/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Mon, 01 Oct 2018 05:24:39 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/cyberpower-systems-8-port-surge-protector-powerboard-with-2x-usb-2-4a-quick-charge-ports/</guid>

					<description><![CDATA[&#160;

<b>CyberPower CPSURGE08USB-ANZ?</b>surge suppressor is ideal for safeguarding your home theater and IT equipment from damage caused by electrical surges. The outlets with MOV technology guard the connected electronic equipment against power irregularities and lightning strikes, while EMI/RFI noise filtering reduces frequency interference, effectively improving picture and sound quality in audio/video systems.

&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<p>The CyberPower Home Theatre AV &amp; Office Series CPSURGE08USB-ANZ Surge Protector PowerBoard is ideal for home entertainment and Home Office protection with 2750 joules, 8 outlets, and a 2.1 meter cord. The surge suppressor provides protection for HDTVs, cable/satellite receivers, personal computers, cable modems, phones/fax/DSL, printers, stereos, and CD/DVD players.</p>
<p>The CPSURGE08USB-ANZ features 8 outlets, MOV technology to guard the surge suppressor and connected electronics against line abnormalities and lightning surges, while EMI/RFI filters block unwanted line noise.</p>
<p>A Limited-Lifetime Warranty ensures that this surge suppressor has passed our highest quality standards in design, assembly, material or workmanship and further protection is offered by a $50,000 Connected Equipment Guarantee.</p>
<p>Features &amp; Benefits:</p>
<ul>
<li>Built-In Automatic Shutdown-In the event of an overload that exceeds the unit&#8217;s ability to suppress the signal, the surge protectors? 10A circuit breaker will automatically switch off to protect all connected electronics.</li>
<li>MOV (Metal Oxide Varistor) &#8211; MOV technology allows normal current to pass through the device, while diverting any surge/spikes through the ground circuit. This safely protects all connected electronics along with the surge suppressor itself.</li>
<li>2x USB 2.4A QUICK CHARGE Ports Included</li>
<li>Limited Lifetime Warranty &#8211; Stringent manufacturing processes and innovative product design enables CyberPower to offer one of the strongest warranties in the industry. CyberPower will repair or replace damaged units for as long as the original owner has the product.</li>
</ul>
<p><strong>PRODUCT SPECS</strong></p>
<table border="0" width="99%" cellspacing="0" cellpadding="0" align="center">
<tbody>
<tr bgcolor="#CCCCCC">
<td width="211"></td>
<td width="349"></td>
</tr>
<tr bgcolor="#CCCCCC">
<td width="211">Part Number</td>
<td width="349">CPSURGE08USB-ANZ</td>
</tr>
<tr bgcolor="#CCCCCC">
<td colspan="2">Input</td>
</tr>
<tr>
<td width="211">Voltage</td>
<td width="349">240Vac</td>
</tr>
<tr>
<td width="211">Frequency</td>
<td width="349">50Hz</td>
</tr>
<tr>
<td width="211">Circuit Breaker</td>
<td width="349">10Amps Resettable</td>
</tr>
<tr>
<td width="211">Cord Length</td>
<td width="349">2.10 meter</td>
</tr>
<tr>
<td width="211">Plug Type</td>
<td width="349">AU Plug</td>
</tr>
<tr bgcolor="#CCCCCC">
<td colspan="2">Output</td>
</tr>
<tr>
<td width="211">Outlet Type</td>
<td width="349">AU</td>
</tr>
<tr>
<td width="211">Outlets &#8211; Total</td>
<td width="349">8</td>
</tr>
<tr>
<td width="211">Outlets &#8211; Energy Saving</td>
<td width="349">0</td>
</tr>
<tr>
<td width="211">USB 2.4A Charging Ports</td>
<td width="349">2</td>
</tr>
<tr bgcolor="#CCCCCC">
<td colspan="2">Surge Protection &amp; Filtering</td>
</tr>
<tr>
<td width="211">Surge Suppression</td>
<td width="349">2,750 Joules</td>
</tr>
<tr>
<td width="211">Maximum Peak Current</td>
<td width="349">67,500 Amps</td>
</tr>
<tr>
<td width="211">Maximum Surge Current H-N</td>
<td width="349">37,500 Amps</td>
</tr>
<tr>
<td width="211">Maximum Surge Current H-G</td>
<td width="349">15,000 Amps</td>
</tr>
<tr>
<td width="211">Maximum Surge Current N-G</td>
<td width="349">15,000 Amps</td>
</tr>
<tr>
<td width="211">Clamping Voltage</td>
<td width="349">L-N, L-G, N-G 1200V</td>
</tr>
<tr>
<td width="211">Response Time</td>
<td width="349">&lt; 1 nanosecond</td>
</tr>
<tr>
<td width="211">Phone Protection RJ11</td>
<td width="349">1-In, 1-Out</td>
</tr>
<tr>
<td width="211">Attenuation</td>
<td width="349">Up to 32dB</td>
</tr>
<tr>
<td width="211">EMI/RFI Filtration</td>
<td width="349">150 kHz to 100 MHz</td>
</tr>
<tr>
<td width="211"></td>
<td width="349"></td>
</tr>
<tr>
<td width="211"></td>
<td width="349"></td>
</tr>
<tr bgcolor="#CCCCCC">
<td colspan="2">Indicators</td>
</tr>
<tr>
<td width="211">Indicators</td>
<td width="349">Protected (Green), Grounded (Green)</td>
</tr>
<tr>
<td width="211">Grounded</td>
<td width="349">Yes</td>
</tr>
<tr>
<td width="211">Protected</td>
<td width="349">Yes</td>
</tr>
<tr bgcolor="#CCCCCC">
<td colspan="2">Warranty</td>
</tr>
<tr>
<td width="211">Product Warranty</td>
<td width="349">Limited Lifetime</td>
</tr>
<tr>
<td width="211">Connected Equipment Guarantee</td>
<td width="349">Lifetime</td>
</tr>
<tr>
<td width="211">CEG Amount</td>
<td width="349">$50,000</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		