<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Best online Double Conversion UPS in Australia</title>
	<atom:link href="https://uptimes.com.au/product-category/shop-by-products/uninterruptible-power-supply-ups-systems/online-double-conversion/feed/" rel="self" type="application/rss+xml" />
	<link>https://uptimes.com.au/product-category/shop-by-products/uninterruptible-power-supply-ups-systems/online-double-conversion/</link>
	<description>Australia’s Power Protection &#38; IT Infrastructure Experts</description>
	<lastBuildDate>Fri, 23 Oct 2026 04:06:15 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://uptimes.com.au/wp-content/uploads/cropped-Uptimes-System-1-32x32.png</url>
	<title>Best online Double Conversion UPS in Australia</title>
	<link>https://uptimes.com.au/product-category/shop-by-products/uninterruptible-power-supply-ups-systems/online-double-conversion/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Uptime ULTIMATE Series 10000VA/10KW Onli...</title>
		<link>https://uptimes.com.au/product/uptime-ultimate-series-10000va/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 01:45:23 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-ultimate-series-10000va/</guid>

					<description><![CDATA[Uptime ULTIMATE Series &#8212; 10000VA / 10000W Online Double-Conversion Tower UPS True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &#8212; continuous, clean, uninterrupted power for servers, network and business-critical equipment. Key features Online double conversion with full digital control Pure sine-wave output Cold start function Intelligent fan-speed regulation Generator [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>Uptime ULTIMATE Series &mdash; 10000VA / 10000W Online Double-Conversion Tower UPS</strong></h3>
<p>True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &mdash; continuous, clean, uninterrupted power for servers, network and business-critical equipment.</p>
<p><strong><b>Key features</b></strong></p>
<ul>
<li>Online double conversion with full digital control</li>
<li>Pure sine-wave output</li>
<li>Cold start function</li>
<li>Intelligent fan-speed regulation</li>
<li>Generator compatible</li>
<li>Expandable battery runtime (optional external battery cabinet)</li>
</ul>
<p><strong><b>Technical specification &mdash; MODEL UPT-UL10000LCD</b></strong></p>
<ul>
<li>Capacity &mdash; 10000VA / 10000W</li>
<li>Input voltage &mdash; 110&ndash;300 Vac (176&ndash;264 Vac @ 100% load); nominal 208/220/230/240 Vac</li>
<li>Input power factor &mdash; &ge;0.99</li>
<li>Frequency range &mdash; 40&ndash;70 Hz (50/60 Hz auto-sensing)</li>
<li>Output voltage &mdash; 208/220/230/240 Vac, &plusmn;1% regulation</li>
<li>Output power factor &mdash; 1.0</li>
<li>Output waveform &mdash; Pure sine wave</li>
<li>Voltage THD &mdash; &lt;1% linear load, &lt;3% non-linear load</li>
<li>Transfer time &mdash; 0 ms (AC &harr; battery)</li>
<li>Battery &mdash; VRLA, 192 (default) / 216 / 240 Vdc, 9Ah (7Ah optional)</li>
<li>Efficiency &mdash; AC mode up to 95.5%, ECO mode up to 99.0%</li>
<li>Input breaker &mdash; 63A</li>
<li>Dimensions (W&times;D&times;H) &mdash; 191 x 460 x 337 mm (electronics)</li>
<li>Communication &mdash; Blue LCD display; USB / RS232; SNMP card &amp; relay card (optional)</li>
<li>Operating temperature &mdash; 0&ndash;40&deg;C</li>
<li>Standards &mdash; IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime ULTIMATE Series 6000VA/6KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-ultimate-series-6000va/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 01:44:59 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-ultimate-series-6000va/</guid>

					<description><![CDATA[Uptime ULTIMATE Series &#8212; 6000VA / 6000W Online Double-Conversion Tower UPS True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &#8212; continuous, clean, uninterrupted power for servers, network and business-critical equipment. Key features Online double conversion with full digital control Pure sine-wave output Cold start function Intelligent fan-speed regulation Generator [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>Uptime ULTIMATE Series &mdash; 6000VA / 6000W Online Double-Conversion Tower UPS</strong></h3>
<p>True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &mdash; continuous, clean, uninterrupted power for servers, network and business-critical equipment.</p>
<p><strong><b>Key features</b></strong></p>
<ul>
<li>Online double conversion with full digital control</li>
<li>Pure sine-wave output</li>
<li>Cold start function</li>
<li>Intelligent fan-speed regulation</li>
<li>Generator compatible</li>
<li>Expandable battery runtime (optional external battery cabinet)</li>
</ul>
<p><strong><b>Technical specification &mdash; MODEL UPT-UL6000LCD</b></strong></p>
<ul>
<li>Capacity &mdash; 6000VA / 6000W</li>
<li>Input voltage &mdash; 110&ndash;300 Vac (176&ndash;264 Vac @ 100% load); nominal 208/220/230/240 Vac</li>
<li>Input power factor &mdash; &ge;0.99</li>
<li>Frequency range &mdash; 40&ndash;70 Hz (50/60 Hz auto-sensing)</li>
<li>Output voltage &mdash; 208/220/230/240 Vac, &plusmn;1% regulation</li>
<li>Output power factor &mdash; 1.0</li>
<li>Output waveform &mdash; Pure sine wave</li>
<li>Voltage THD &mdash; &lt;1% linear load, &lt;3% non-linear load</li>
<li>Transfer time &mdash; 0 ms (AC &harr; battery)</li>
<li>Battery &mdash; VRLA, 192 (default) / 216 / 240 Vdc, 7Ah (9Ah optional)</li>
<li>Efficiency &mdash; AC mode up to 95.0%, ECO mode up to 98.8%</li>
<li>Input breaker &mdash; 40A</li>
<li>Dimensions (W&times;D&times;H) &mdash; 191 x 460 x 337 mm (electronics)</li>
<li>Communication &mdash; Blue LCD display; USB / RS232; SNMP card &amp; relay card (optional)</li>
<li>Operating temperature &mdash; 0&ndash;40&deg;C</li>
<li>Standards &mdash; IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime ULTIMATE Series 3000VA/3KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-ultimate-series-3000va/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 01:44:35 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-ultimate-series-3000va/</guid>

					<description><![CDATA[Uptime ULTIMATE Series &#8212; 3000VA / 3000W Online Double-Conversion Tower UPS True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &#8212; continuous, clean, uninterrupted power for servers, network and business-critical equipment. Key features Online double conversion with full digital control Pure sine-wave output Cold start function Intelligent fan-speed regulation Generator [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>Uptime ULTIMATE Series &mdash; 3000VA / 3000W Online Double-Conversion Tower UPS</strong></h3>
<p>True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &mdash; continuous, clean, uninterrupted power for servers, network and business-critical equipment.</p>
<p><strong><b>Key features</b></strong></p>
<ul>
<li>Online double conversion with full digital control</li>
<li>Pure sine-wave output</li>
<li>Cold start function</li>
<li>Intelligent fan-speed regulation</li>
<li>Generator compatible</li>
<li>Expandable battery runtime (optional external battery cabinet)</li>
</ul>
<p><strong><b>Technical specification &mdash; MODEL UPT-UL3000LCD</b></strong></p>
<ul>
<li>Capacity &mdash; 3000VA / 3000W</li>
<li>Input voltage &mdash; 110&ndash;300 Vac (176&ndash;264 Vac @ 100% load); nominal 208/220/230/240 Vac</li>
<li>Input power factor &mdash; &ge;0.99</li>
<li>Frequency range &mdash; 40&ndash;70 Hz (50/60 Hz auto-sensing)</li>
<li>Output voltage &mdash; 208/220/230/240 Vac, &plusmn;1% regulation</li>
<li>Output power factor &mdash; 0.9</li>
<li>Output waveform &mdash; Pure sine wave</li>
<li>Voltage THD &mdash; &le;3% linear load, &le;5% non-linear load</li>
<li>Transfer time &mdash; 0 ms (AC &harr; battery)</li>
<li>Battery &mdash; 6 x 12V, 9Ah (7Ah optional)</li>
<li>Efficiency &mdash; AC mode up to 91%</li>
<li>Dimensions (W&times;D&times;H) &mdash; 191 x 460 x 337 mm</li>
<li>Communication &mdash; Blue LCD display; USB / RS232; SNMP card &amp; relay card (optional)</li>
<li>Operating temperature &mdash; 0&ndash;40&deg;C</li>
<li>Standards &mdash; IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime ULTIMATE Series 2000VA/2KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-ultimate-series-2000va/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 01:44:11 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-ultimate-series-2000va/</guid>

					<description><![CDATA[Uptime ULTIMATE Series &#8212; 2000VA / 2000W Online Double-Conversion Tower UPS True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &#8212; continuous, clean, uninterrupted power for servers, network and business-critical equipment. Key features Online double conversion with full digital control Pure sine-wave output Cold start function Intelligent fan-speed regulation Generator [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>Uptime ULTIMATE Series &mdash; 2000VA / 2000W Online Double-Conversion Tower UPS</strong></h3>
<p>True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &mdash; continuous, clean, uninterrupted power for servers, network and business-critical equipment.</p>
<p><strong><b>Key features</b></strong></p>
<ul>
<li>Online double conversion with full digital control</li>
<li>Pure sine-wave output</li>
<li>Cold start function</li>
<li>Intelligent fan-speed regulation</li>
<li>Generator compatible</li>
<li>Expandable battery runtime (optional external battery cabinet)</li>
</ul>
<p><strong><b>Technical specification &mdash; MODEL UPT-UL2000LCD</b></strong></p>
<ul>
<li>Capacity &mdash; 2000VA / 2000W</li>
<li>Input voltage &mdash; 110&ndash;300 Vac (176&ndash;264 Vac @ 100% load); nominal 208/220/230/240 Vac</li>
<li>Input power factor &mdash; &ge;0.99</li>
<li>Frequency range &mdash; 40&ndash;70 Hz (50/60 Hz auto-sensing)</li>
<li>Output voltage &mdash; 208/220/230/240 Vac, &plusmn;1% regulation</li>
<li>Output power factor &mdash; 0.9</li>
<li>Output waveform &mdash; Pure sine wave</li>
<li>Voltage THD &mdash; &le;3% linear load, &le;5% non-linear load</li>
<li>Transfer time &mdash; 0 ms (AC &harr; battery)</li>
<li>Battery &mdash; 4 x 12V, 9Ah (7Ah optional)</li>
<li>Efficiency &mdash; AC mode up to 90%</li>
<li>Dimensions (W&times;D&times;H) &mdash; 191 x 460 x 337 mm</li>
<li>Communication &mdash; Blue LCD display; USB / RS232; SNMP card &amp; relay card (optional)</li>
<li>Operating temperature &mdash; 0&ndash;40&deg;C</li>
<li>Standards &mdash; IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime ULTIMATE Series 1000VA/1KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-ultimate-series-1000va/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 01:43:46 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-ultimate-series-1000va/</guid>

					<description><![CDATA[Uptime ULTIMATE Series &#8212; 1000VA / 1000W Online Double-Conversion Tower UPS True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &#8212; continuous, clean, uninterrupted power for servers, network and business-critical equipment. Key features Online double conversion with full digital control Pure sine-wave output Cold start function Intelligent fan-speed regulation Generator [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3><strong>Uptime ULTIMATE Series &mdash; 1000VA / 1000W Online Double-Conversion Tower UPS</strong></h3>
<p>True online double-conversion (VFI) tower UPS with pure sine-wave output and full digital control &mdash; continuous, clean, uninterrupted power for servers, network and business-critical equipment.</p>
<p><strong><b>Key features</b></strong></p>
<ul>
<li>Online double conversion with full digital control</li>
<li>Pure sine-wave output</li>
<li>Cold start function</li>
<li>Intelligent fan-speed regulation</li>
<li>Generator compatible</li>
<li>Expandable battery runtime (optional external battery cabinet)</li>
</ul>
<p><strong><b>Technical specification &mdash; MODEL UPT-UL1000LCD</b></strong></p>
<ul>
<li>Capacity &mdash; 1000VA / 1000W</li>
<li>Input voltage &mdash; 110&ndash;300 Vac (176&ndash;264 Vac @ 100% load); nominal 208/220/230/240 Vac</li>
<li>Input power factor &mdash; &ge;0.99</li>
<li>Frequency range &mdash; 40&ndash;70 Hz (50/60 Hz auto-sensing)</li>
<li>Output voltage &mdash; 208/220/230/240 Vac, &plusmn;1% regulation</li>
<li>Output power factor &mdash; 0.9</li>
<li>Output waveform &mdash; Pure sine wave</li>
<li>Voltage THD &mdash; &le;3% linear load, &le;5% non-linear load</li>
<li>Transfer time &mdash; 0 ms (AC &harr; battery)</li>
<li>Battery &mdash; 2 x 12V, 9Ah (7Ah optional)</li>
<li>Efficiency &mdash; AC mode up to 88%</li>
<li>Dimensions (W&times;D&times;H) &mdash; 144 x 293 x 209 mm</li>
<li>Communication &mdash; Blue LCD display; USB / RS232; SNMP card &amp; relay card (optional)</li>
<li>Operating temperature &mdash; 0&ndash;40&deg;C</li>
<li>Standards &mdash; IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime DC Max Series 1000VA/1KW Online D...</title>
		<link>https://uptimes.com.au/product/uptime-systems-dc-max-series-1000va-1kw/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Wed, 14 Oct 2026 06:58:59 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-systems-dc-max-series-1000va-1kw/</guid>

					<description><![CDATA[⇩ Download DC Max brochure (PDF) ⇩ UPS Management Software Technical Specification MODEL UPT-IOTRT1000LCD VA/Watt &#8211; 1000VA/1000W INPUT PERFORMANCE Voltage range &#8211; 110~300Vac (176~264Vac @ 100% load) Nominal Frequency &#8211; 50Hz/60Hz Frequency Range &#8211; 40Hz-70Hz (50/60Hz Auto-Sensing) PF &#8211; &#62;0.99 THDI &#8211; &#60;5% INPUT CONNECTION &#8211; 1x IEC C14 OUTPUT PERFORMANCE Nominal Voltage &#8211; 220/230/240 [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="dcmax-brochure" style="margin: 0 0 18px;"><a style="display: inline-block; background: #CC3366; color: #fff; font-weight: bold; padding: 12px 22px; border-radius: 8px; text-decoration: none;" href="https://uptimes.com.au/wp-content/uploads/dc-max-series-brochure.pdf" target="_blank" rel="noopener">⇩ Download DC Max brochure (PDF)</a> <a style="display: inline-block; background: #1F6FB2; color: #fff; font-weight: bold; padding: 12px 22px; border-radius: 8px; text-decoration: none; margin-left: 8px;" href="http://download.ksdatacloud.com/#Shutdown" target="_blank" rel="noopener">⇩ UPS Management Software</a></div>
<h3><strong><b>Technical Specification</b></strong></h3>
<p><strong><b>MODEL UPT-IOTRT1000LCD</b></strong></p>
<ul>
<li>VA/Watt &#8211; 1000VA/1000W</li>
</ul>
<p><strong><b>INPUT PERFORMANCE</b></strong></p>
<ul>
<li>Voltage range &#8211; 110~300Vac (176~264Vac @ 100% load)</li>
<li>Nominal Frequency &#8211; 50Hz/60Hz</li>
<li>Frequency Range &#8211; 40Hz-70Hz (50/60Hz Auto-Sensing)</li>
<li>PF &#8211; &gt;0.99</li>
<li>THDI &#8211; &lt;5%</li>
</ul>
<p><strong><b>INPUT CONNECTION &#8211; 1x IEC C14</b></strong></p>
<p><strong><b>OUTPUT PERFORMANCE</b></strong></p>
<ul>
<li>Nominal Voltage &#8211; 220/230/240 VAC</li>
<li>Nominal Frequency &#8211; 50Hz/60Hz</li>
<li>Maximum PF &#8211; PF = 1</li>
<li>Voltage Accuracy &#8211; ±1%</li>
<li>THDv &#8211; &lt;3% linear load; &lt;5% nonlinear load</li>
<li>Crest Ratio &#8211; Max 3:1</li>
<li>Overload &#8211; 105%~125%: transfer to bypass after 1 minute; 125%~130%: after 30 seconds; &gt;130%: immediately (when utility is normal)</li>
<li>Socket &#8211; 1 main outlet group (with 4 x IEC C13); 1 programmable outlet group (with 4 x IEC C13)</li>
<li>Load Segment Control &#8211; 1 programmable load segment control</li>
</ul>
<p><strong><b>BATTERY</b></strong></p>
<ul>
<li>Capacity (AH) &#8211; 3 x 12V (7/9Ah)</li>
</ul>
<p><strong><b>MAXIMUM EBM QUANTITY &#8211; 4</b></strong></p>
<p><strong><b>EBM AUTO DETECTION &#8211; YES</b></strong></p>
<p><strong><b>OTHER MODE</b></strong></p>
<ul>
<li>CVCF &#8211; Yes</li>
</ul>
<p><strong><b>HMI</b></strong></p>
<ul>
<li>Display &#8211; Dot matrix LCD</li>
</ul>
<p><strong><b>COMMUNICATION</b></strong></p>
<ul>
<li>Port &#8211; USB (or RS232), SNMP card (optional), Relay card (optional)</li>
</ul>
<p><strong><b>PHYSICAL</b></strong></p>
<ul>
<li>Dimension (W*D*H) &#8211; 440 x 325 x 86.5 mm (2U)</li>
<li>Operating Temperature &#8211; 0-40°C</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime SNMP Card to Suit DC Max and Ulti...</title>
		<link>https://uptimes.com.au/product/uptime-systems-snmp-card-to-suit-rtx-dc-max-series-rack-tower-ups-models/</link>
		
		<dc:creator><![CDATA[Lorena]]></dc:creator>
		<pubDate>Mon, 13 May 2024 03:43:22 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/product/uptime-systems-snmp-card-to-suit-rtx-dc-max-series-rack-tower-ups-models/</guid>

					<description><![CDATA[Key feature • Ideal monitoring solution enables the user to monitor and control the status of the Uninterruptible Power Supply on web browser via the internet • Communicates with UPS and responds to the Network Management System using SNMP (Simple Network Management Protocol) • Supports RTC (Real-Time Clock) • Supports software to shut down the [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Key feature<br />
• Ideal monitoring solution enables the user to monitor and control the status of the Uninterruptible Power Supply on<br />
web browser via the internet<br />
• Communicates with UPS and responds to the Network Management System using<br />
SNMP (Simple Network Management Protocol)<br />
• Supports RTC (Real-Time Clock)<br />
• Supports software to shut down the server or client operating system safely<br />
during the power failure</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime DC Max Series 10000VA/10KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-systems-dc-max-series-10000va-10kw/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 05 Mar 2024 03:06:35 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=31769</guid>

					<description><![CDATA[⇩ Download DC Max brochure (PDF) &#8681; UPS Management Software Technical Specification MODEL UPT-IOTRT10000 VA/Watt &#8211; 10KVA/10KW INPUT PERFORMANCE Voltage range (Phase voltage) &#8211; 110Vac-276Vac Nominal Frequency &#8211; 220/230/240VAC OUTPUT PERFORMANCE Rated voltage (Phase voltage) &#8211; 220/230/240VAC Overload on normal mode &#8211; 105%-125% Load, 10 minutes transfer to Bypass; 125%-150% Load, 30 seconds transfer to [&#8230;]]]></description>
										<content:encoded><![CDATA[<div class="dcmax-brochure" style="margin: 0 0 18px;"><a style="display: inline-block; background: #CC3366; color: #fff; font-weight: bold; padding: 12px 22px; border-radius: 8px; text-decoration: none;" href="https://uptimes.com.au/wp-content/uploads/dc-max-series-brochure.pdf" target="_blank" rel="noopener">⇩ Download DC Max brochure (PDF)</a> <a style="display:inline-block;background:#1F6FB2;color:#fff;font-weight:700;padding:12px 22px;border-radius:8px;text-decoration:none;margin-left:8px;" href="http://download.ksdatacloud.com/#Shutdown" target="_blank" rel="noopener">&#8681; UPS Management Software</a></div>
<h3><strong><b>Technical Specification</b></strong></h3>
<p><strong><b>MODEL UPT-IOTRT10000</b></strong></p>
<ul>
<li>VA/Watt &#8211; 10KVA/10KW</li>
</ul>
<p><strong><b>INPUT PERFORMANCE</b></strong></p>
<ul>
<li>Voltage range (Phase voltage) &#8211; 110Vac-276Vac</li>
<li>Nominal Frequency &#8211; 220/230/240VAC</li>
</ul>
<p><strong><b>OUTPUT PERFORMANCE</b></strong></p>
<ul>
<li>Rated voltage (Phase voltage) &#8211; 220/230/240VAC</li>
<li>Overload on normal mode &#8211; 105%-125% Load, 10 minutes transfer to Bypass;<br />
125%-150% Load, 30 seconds transfer to Bypass;<br />
&gt;150% Load, 0.5 seconds transfer to Bypass</li>
<li>Short-circuit current in normal mode &#8211; 113A for 200ms max</li>
</ul>
<p><strong><b>Transfer Time Line &lt;-&gt; </b></strong>Battery &#8211; 0ms</p>
<p><strong><b>Transfer Time Inv&lt;-&gt;</b></strong> Bypass- 0ms</p>
<p><strong>Battery Voltage</strong> &#8211; 240VDC</p>
<p><strong>Battery Number </strong>&#8211; 20PCS</p>
<p><strong>Other Mode</strong></p>
<ul>
<li>CVCF &#8211; Yes (derating to 60% load)</li>
</ul>
<p><strong><b>HMI </b></strong></p>
<ul>
<li>Display &#8211; Dot matrix LCD (optional segment LCD)</li>
</ul>
<p><strong><b>COMMUNICATION</b></strong></p>
<ul>
<li>Port &#8211; USB, RS232, Dry in/out, RPO, IOT Ethernet port</li>
<li>Monitor Software &#8211; Winpower, Winpower View APP</li>
</ul>
<p><strong><b>DIMENSION (W*D*H) mm</b></strong> &#8211; 438*540*86.3</p>
<p><strong><b>ENVIRONMENT</b></strong></p>
<ul>
<li>Ambient Temperature &#8211; o⁰C ~ 50⁰C (Derating 50% above 40⁰C)</li>
</ul>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime DC Max Series 3000VA/3KW Online D...</title>
		<link>https://uptimes.com.au/product/uptime-systems-dc-max-series-3000va-3kw/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 08 Feb 2024 05:01:03 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=31751</guid>

					<description><![CDATA[<ul>
 	<li>True double-conversion design with high adaptability to harsh mains conditions</li>
 	<li>Real PF 1 can provide more power in same space</li>
 	<li>High efficiency results in energy saving</li>
 	<li>Adjustable charging current and flexible battery configuration</li>
 	<li>Optimized changing method to expand battery life time.</li>
 	<li>Built-in OVCD protection, fan lock detection, over temperature detection, overload warning to enhance the product reliability</li>
 	<li>Programmable outlet group will extend back up time for most critical equipment (6-10K need PDU model)</li>
 	<li>Automatic detect additional EBM quantity will simplify EBM installation for IT users</li>
 	<li>Compact size requiring small installation space</li>
 	<li>Hot swappable battery will save customer service cost (For 1-3K standard UPS model)</li>
 	<li>Low audible noise at typical load</li>
 	<li>Dot matrix LCD support up to 10 languages for easy installation and service.</li>
 	<li>Embedded Ethernet port solution provide safe network connection to Cloud which will meet the increasing IoT trend</li>
 	<li>WLAN module for IoT connection</li>
 	<li>Mobile APP for monitoring, configuration. Support Android/iOS</li>
 	<li>USB HID enable monitoring on UPS without software installation</li>
 	<li>Dry contactor for industrial condition</li>
 	<li>Upgraded network card compliance with IEC standard cybersecurity</li>
</ul>
&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<div class="dcmax-brochure" style="margin:0 0 18px;"><a href="https://uptimes.com.au/wp-content/uploads/dc-max-series-brochure.pdf" target="_blank" rel="noopener" style="display:inline-block;background:#CC3366;color:#fff;font-weight:700;padding:12px 22px;border-radius:8px;text-decoration:none;">&#8681; Download DC Max brochure (PDF)</a> <a style="display:inline-block;background:#1F6FB2;color:#fff;font-weight:700;padding:12px 22px;border-radius:8px;text-decoration:none;margin-left:8px;" href="http://download.ksdatacloud.com/#Shutdown" target="_blank" rel="noopener">&#8681; UPS Management Software</a></div>
<h3><strong><b>Technical Specification</b></strong></h3>
<p><strong><b>MODEL UPT-IOTRT3000LCD</b></strong></p>
<ul>
<li>VA/Watt &#8211; 3000VA/3000W</li>
</ul>
<p><strong><b>INPUT PERFORMANCE</b></strong></p>
<ul>
<li>Voltage range &#8211; 230-300V 100% load, 110-230V derating to 40% load linearly</li>
<li>Nominal Frequency &#8211; 50Hz/60Hz</li>
<li>Frequency Range &#8211; 40Hz-70Hz (45Hz-55Hz, 54Hz-66Hz @ load&gt;60%)</li>
<li>PF &#8211; &gt;0.99</li>
<li>THDI &#8211; &lt;5%</li>
</ul>
<p><strong><b>INPUT CONNECTION &#8211; 1x IEC C20</b></strong></p>
<p><strong><b>OUTPUT PERFORMANCE</b></strong></p>
<ul>
<li>Nominal Voltage &#8211; 230/230/240 VAC (Nominal voltage 220VAC power derating to 90% of rating power)</li>
<li>Normal Frequency &#8211; 50Hz/60Hz</li>
<li>Maximum PF &#8211; PF =1</li>
<li>Voltage Accuracy &#8211; ±1%</li>
<li>THDv &#8211; &lt;1% linear load; &lt;5% nonlinear load</li>
<li>Transfer time &#8211; 0ms@line &lt;-&gt; battery; 4ms @ line &lt;-&gt; bypass; 10ms @ ECO &lt;-&gt; Inverter</li>
<li>Crest Ratio &#8211; Max 3:1</li>
<li>Overload &#8211; 100%&lt;load≤102% continuous, 102%&lt;load<strong><b>≤</b></strong>125% for minutes</li>
<li>Socket &#8211; 1 main outlet group (with 1 x IEC<br />
C19 + 4 x IEC C13)<br />
1 programmable outlet group<br />
(with 4 x IEC C13)</li>
<li>Load Segment Control &#8211; 1 programmable load segment control</li>
</ul>
<p><strong><b>BATTERY</b></strong></p>
<ul>
<li>Capacity (AH) &#8211; 6 X12V (9Ah)</li>
</ul>
<p><strong><b>MAXIMUM EBM QUANTITY &#8211; 4</b></strong></p>
<p><strong><b>EBM AUTO DETECTION &#8211; YES</b></strong></p>
<p><strong><b>OTHER MODE</b></strong></p>
<ul>
<li>CVCF &#8211; Yes (derating to 60% load)</li>
</ul>
<p><strong><b>HMI</b></strong></p>
<ul>
<li>Display &#8211; Dot matrix LCD (option segment LCD)</li>
</ul>
<p><strong><b>COMMUNICATION</b></strong></p>
<ul>
<li>Port &#8211; USB, RS232, Dry in/out, RPO, IOT Ethernet port</li>
<li>Monitor Software &#8211; Winpower, Winpower View APP</li>
</ul>
<p><strong><b>DIMENSION (W*D*H) mm</b></strong> &#8211;<strong> 438*600*85.5(2U)</strong></p>
<p><strong><b>ENVIRONMENT</b></strong></p>
<ul>
<li>Operating Temperature &#8211; 0-40⁰C</li>
</ul>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Uptime DC Max Series 2000VA/1.8KW Online...</title>
		<link>https://uptimes.com.au/product/uptime-systems-dc-max-series-2000va-1-8kw/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Thu, 08 Feb 2024 04:59:13 +0000</pubDate>
				<guid isPermaLink="false">https://uptimes.com.au/?post_type=product&#038;p=31778</guid>

					<description><![CDATA[<ul>
 	<li>True double-conversion design with high adaptability to harsh mains conditions</li>
 	<li>Real PF 1 can provide more power in same space</li>
 	<li>High efficiency results in energy saving</li>
 	<li>Adjustable charging current and flexible battery configuration</li>
 	<li>Optimized changing method to expand battery life time.</li>
 	<li>Built-in OVCD protection, fan lock detection, over temperature detection, overload warning to enhance the product reliability</li>
 	<li>Programmable outlet group will extend back up time for most critical equipment (6-10K need PDU model)</li>
 	<li>Automatic detect additional EBM quantity will simplify EBM installation for IT users</li>
 	<li>Compact size requiring small installation space</li>
 	<li>Hot swappable battery will save customer service cost (For 1-3K standard UPS model)</li>
 	<li>Low audible noise at typical load</li>
 	<li>Dot matrix LCD support up to 10 languages for easy installation and service.</li>
 	<li>Embedded Ethernet port solution provide safe network connection to Cloud which will meet the increasing IoT trend</li>
 	<li>WLAN module for IoT connection</li>
 	<li>Mobile APP for monitoring, configuration. Support Android/iOS</li>
 	<li>USB HID enable monitoring on UPS without software installation</li>
 	<li>Dry contactor for industrial condition</li>
 	<li>Upgraded network card compliance with IEC standard cybersecurity</li>
</ul>
&#160;

Contact us for Pricing]]></description>
										<content:encoded><![CDATA[<div class="dcmax-brochure" style="margin:0 0 18px;"><a href="https://uptimes.com.au/wp-content/uploads/dc-max-series-brochure.pdf" target="_blank" rel="noopener" style="display:inline-block;background:#CC3366;color:#fff;font-weight:700;padding:12px 22px;border-radius:8px;text-decoration:none;">&#8681; Download DC Max brochure (PDF)</a> <a style="display:inline-block;background:#1F6FB2;color:#fff;font-weight:700;padding:12px 22px;border-radius:8px;text-decoration:none;margin-left:8px;" href="http://download.ksdatacloud.com/#Shutdown" target="_blank" rel="noopener">&#8681; UPS Management Software</a></div>
<h3><strong><b>Technical Specification</b></strong></h3>
<p><strong><b>MODEL UPT-IOTRT2000LCD</b></strong></p>
<ul>
<li>VA/Watt &#8211; 2000VA/2000W*</li>
</ul>
<p><strong><b>INPUT PERFORMANCE</b></strong></p>
<ul>
<li>Voltage range &#8211; 230-300V 100% load, 110-230V derating to 40% load linearly</li>
<li>Nominal Frequency &#8211; 50Hz/60Hz</li>
<li>Frequency Range &#8211; 40Hz-70Hz (45Hz-55Hz, 54Hz-66Hz @ load&gt;60%)</li>
<li>PF &#8211; &gt;0.99</li>
<li>THDI &#8211; &lt;5%</li>
</ul>
<p><strong><b>INPUT CONNECTION &#8211; 1x IEC C14</b></strong></p>
<p><strong><b>OUTPUT PERFORMANCE</b></strong></p>
<ul>
<li>Nominal Voltage &#8211; 230/230/240 VAC (Nominal voltage 220VAC power derating to 90% of rating power)</li>
<li>Normal Frequency &#8211; 50Hz/60Hz</li>
<li>Maximum PF &#8211; PF =1</li>
<li>Voltage Accuracy &#8211; ±1%</li>
<li>THDv &#8211; &lt;1% linear load; &lt;5% nonlinear load</li>
<li>Transfer time &#8211; 0ms@line &lt;-&gt; battery; 4ms @ line &lt;-&gt; bypass; 10ms @ ECO &lt;-&gt; Inverter</li>
<li>Crest Ratio &#8211; Max 3:1</li>
<li>Overload &#8211; 100%&lt;load≤102% continuous, 102%&lt;load<strong><b>≤</b></strong>125% for minutes</li>
<li>Socket &#8211; 1 main outlet group (with 4 x IEC C13)<br />
1 programmable outlet group (with 4 x IEC C13)</li>
<li>Load Segment Control &#8211; 1 programmable load segment control</li>
</ul>
<p><strong><b>BATTERY</b></strong></p>
<ul>
<li>Capacity (AH) &#8211; 6 x 12V (7Ah)</li>
</ul>
<p><strong><b>MAXIMUM EBM QUANTITY &#8211; 4</b></strong></p>
<p><strong><b>EBM AUTO DETECTION &#8211; YES</b></strong></p>
<p><strong><b>OTHER MODE</b></strong></p>
<ul>
<li>CVCF &#8211; Yes (derating to 60% load)</li>
</ul>
<p><strong><b>HMI</b></strong></p>
<ul>
<li>Display &#8211; Dot matrix LCD (option segment LCD)</li>
</ul>
<p><strong><b>COMMUNICATION</b></strong></p>
<ul>
<li>Port &#8211; USB, RS232, Dry in/out, RPO, IOT Ethernet port</li>
<li>Monitor Software &#8211; Winpower, Winpower View APP</li>
</ul>
<p><strong>DIMENSION (W*D*H) mm &#8211; 438*600*85.5(2U)</strong></p>
<p><strong><b>ENVIRONMENT</b></strong></p>
<ul>
<li>Operating Temperature &#8211; 0-40⁰C</li>
</ul>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>