TRIPP LITE Provides UL 60601-1 compliant, medical-grade 700VA/450W power backup, ideal for use in patient-care vicinities. The built-in isolation transformer offers full isolation while maintaining AC surge protection in all modes.
- Supports a half load up to 36 minutes; full load up to 14.5 minutes
- Six IEC320 C13 hospital-grade outlets and IEC320 C14 hospital-grade plug
- Leakage current less than 100 microamps
- Approved for use within the Patient Care Vicinity
- Approved to EN60601-1-2:2015, 4th Edition
- 340 joule surge suppression rating protects connected equipment
- Alarm mute/alarm quiet control is ideal for use around patients
2-year warranty
OVERVIEW
UPC Code |
037332140418 |
UPS Type |
Line-Interactive |
OUTPUT
Output Volt Amp Capacity (VA) |
700 |
Output Watt Capacity (Watts) |
450 |
Nominal Voltage Details |
230v nominal inverter output voltage |
Frequency Compatibility |
50 / 60 Hz |
Frequency Compatibility Details |
Automatic frequency selection |
Output Voltage Regulation (Line Mode) |
-18%, +8% |
Output AC Waveform (Battery Mode) |
PWM sine wave |
Nominal Output Voltage(s) Supported |
220V; 230V; 240V |
Output Receptacles |
(6) C13 |
Individually Controllable Load Banks |
No |
INPUT
Rated input current (Maximum Load) |
3.6A |
Nominal Input Voltage(s) Supported |
230V AC |
UPS Input Connection Type |
C14 inlet |
UPS Input Cord Length (ft.) |
0.50 |
UPS Input Cord Length (m) |
0.2 |
Recommended Electrical Service |
10A 230V |
Voltage Compatibility (VAC) |
230 |
Input Phase |
Single-Phase |
BATTERY
Full Load Runtime (min.) |
14.5 min. (450w) |
Half Load Runtime (min.) |
36 min. (225w) |
DC System Voltage (VDC) |
36 |
Battery Recharge Rate (Included Batteries) |
Less than 3.6 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge |
RBC36SLT |
Battery Access |
Battery access door allows hot swap battery replacement without powering connected equipment off |
Typical Battery Lifespan |
3-6 years, depending on usage |
Expandable Runtime |
No |
VOLTAGE REGULATION
Voltage Regulation Description |
Line interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to 274V AC |
Overvoltage Correction |
Input voltages between 206 and 245V AC are reduced by 9% |
Undervoltage Correction |
Input voltages between 183 and 199 are boosted by 10% |
Severe Undervoltage Correction |
Input voltages between 155 and 182 are boosted by 21% |
USER INTERFACE, ALERTS & CONTROLS
Switches |
Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions |
Audible Alarm |
3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert UPS management software. |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating |
340 |
EMI / RFI AC Noise Suppression |
Yes |
AC Suppression Response Time |
Instantaneous |
PHYSICAL
Cooling Method |
Cooling via rear-exit cooling fan |
Installation Form Factors Supported with Optional Accessories |
Wallmount ( UPSWM - tower mounting kit) |
Primary Form Factor |
Tower |
Primary UPS Depth (mm) |
229 |
Primary UPS Height (mm) |
325 |
Primary UPS Width (mm) |
191 |
Shipping Dimensions (hwd / cm) |
46.99 x 30.99 x 33.99 |
Shipping Weight (kg) |
20.59 |
UPS Housing Material |
PVC |
UPS Power Module Dimensions (hwd, cm) |
32.51 x 19.05 x 22.86 |
UPS Power Module Weight (kg) |
19.10 |
ENVIRONMENTAL
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
208.6 |
Battery Mode BTU / Hr. (Full Load) |
189.1 |
COMMUNICATIONS
Communications Interface |
USB; DB9 Serial |
LINE / BATTERY TRANSFER
Transfer Time |
5 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) |
155 |
High Voltage Transfer to Battery Power (Setpoint) |
274 |
SPECIAL FEATURES
Grounding Lug |
Equipotential connection (back panel grounding lug) |
Cold Start (Startup in Battery Mode During a Power Failure) |
Cold-start operation supported |
CERTIFICATIONS
UPS Certifications |
CE; Tested to UL60601-1 (medical grade) |
WARRANTY
Product Warranty Period (International) |
2-year warranty |